Bone necrosis caused by over compression during insertion of implant after tooth removal. 

Symptoms include resorption of bone around compressed area, radiolucency on radiograph (c)

Complaint from the patient about continuous discomfort

Solution is to remove implant and affected tissue (d)

Graft the area for delayed new implant placement